Basic Info.
Classification
Lighting/Power
Standby UPS
Sine Wave Output UPS
Equipment Mode
Centralized Model
Mode
Intelligent Mode, AC Mode, DC Mode
Transport Package
Export Standard Pacakge
Specification
800× 1200× 2260
Product Description
CND310 series Electricity Special UPS
The CND310 series Electricity Special UPS system consists of system cabinet, DBW bypass stabilized cabinet, and PDU feeder cabinet. CONSNANT designs exclusively for power plant, transformer substation, and distribution substation according to the development requirement of China Power. It possesses on-line double conversion and zero transfer function.
It can be mainly applied for power system telemechanics, PTU, power line carrier, power system monitoring and so on. After being isolated and filtered by regulator, Single-phase 220V or three-phase 380V can provide stable power for load through inverter when the AC is normal. If the failure of AC power grid supply or a power cut occurs, the backup of DC power system can invert to supply electricity through the reverse diode. If the DC Power System is under voltage or cut off, the static switch will turn to bypass automatically. When the AC power is recover, the static switch will turn to AC power automatically. If the inverter is overloaded or fault, the system will turn to bypass and indicates a warning signal at the same time.
Key Features:
Adopt full digital control technology
Intelligent detection and monitoring function
Digitally control the static switch with zero switch
Full isolation between input and output
Super low output zero earth voltage
DC UPS isolated with utility power completely
Cubical design with power standard (customization)
Multifunctional protection for overvoltage, under voltage, over current, short circuit and over temperature and so on.
Large-screen LCD monitor with Chinese and English operation interface
Ultralong 256 event record, user-friendly analysis and management to the situation of the power supply (touch screen optional)
Static bypass has a strong anti-overload capability
Control system:
It adopts microprocessor bus control technology, three core processor controlling rectification, inversion and parallel connection respectively, to ensure the real-time control of the rectifier, inverter and static switch and the coordination of every power part, characterized by increased control of aging, higher reliability, enhance of the efficiency of the whole UPS system and the output technical parameters are better than that of the device with same capacity.
Rectifier:
6 pulse or 12 pulse fully controlled bridge (6 or 12 SCR) compose rectifier. Its function is to input AC 3880V to DC220V or so by rectification. "slope" start (soft start) is the control feature, which means output voltage of the rectifier increase from 0V to 220V within 10 second and has no impact on the power grid.
Inverter:
SPWM(sinusoidal pulse width modulation) , formed by 6 IBGT high power tubes, is composed of full-bridge-control. Its function is to transform DC voltage into sinusoidal AC voltage, boosting by the special (△/Y) zero phase shift zigzag type isolation transformer and become AC220V as load required. In addition, the transformer can eliminate like triple harmonics current that are reflected by non linear load from computer. Control features is the adoption of the "slow-down gate voltage" protection technology, greatly reducing disturbance of shutoff of the inverter (inverter and static switch shift mutually ), enhancing the overload capacity of the whole UPS system, which make the capability of anti-short circuit and anti overload of UPS far superior to the ordinary UPS, especially the anti shot circuit is unmatched by similar devices.
Large Capacity of Overload of the UPS Inverter:
110% load --60'
125% load --10'
150% load --1'
200% single phase load --30"
Good Capacity of Resistance to Output Short Circuit Current Limiting and Period Load Impact
Advantages:
290% rated current -- 5": Even though a output short circuit or an overload occurs because of user's improper operation, the output current of UPS can still be limited to a controllable extent instead of exceedingly increasing, consequently laying a good foundation for a long-term and reliable operation of UPS.
Static switch:
Not sync automatically switch:
When the bypass of the UPS lose sync with the inverter, system can automatically implement not sync switch, for example, when the utility power surge pulse width <5ms, the system can ensure no power cutoff.
When the bypass exceed the limitation, UPS will detect the bypass every 20ms, when the phase angle difference of bypass and the inverter turn to normal range, not synchronized bypass shifting can be realized.
Optional bypass cabinet:
Isolating transformer and the bypass voltage regulation
Intelligent monitoring:
Working status and data of UPS are transmitted to DCS system in real-time via RS232/RS485, passive contact and power transmitter, which finally realize Intelligent monitoring.
Unique option:
SNMP card
Dry contact card
Signal transmitter
Bypass isolation and voltage regulation
Increase feeder circuit (standard for 8 loops)
12 pulse rectifier
The appearance of special models(standard dimension:800×600×2260mm)
CND310 10KVA-100KVA |
Model Number | 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA 100KVA |
Rating capacity | 8KW 12KW 16KW 24KW 32KW 40KW 48KW 64KW 80KW |
Rating voltage | 220VAC Single Phase(6-20KVA)/380VAC Three Phase |
AC input |
Voltage range | ±25% |
Frequency range | 50/60Hz±10% |
Soft start | 0-100% in 5" |
Power factor | 0.95(with input filter) |
Bypass input |
Permitted voltage range | ±15% |
Frequency range | 50/60Hz±5% |
Output |
Voltage accuracy | 220V±1%(steady load) 220V±3%( fluctuating load) |
Permitted Frequency range | 50/60Hz±0.05Hz(powered by battery) |
Power factor | 0.8 |
Waveform | Linearload<2%, non linear load<4% |
Dynamic transients | <5% |
Current crest ratio | 3:1 |
Overload capacity | Normal in 110% load, 125% for 10min |
Efficiency | Double switch:94%, ECO:98% |
DC |
Battery voltage | 220V; (10-40KVA 110V is optional) |
Cutoff voltage | 185V |
Maximum discharge current | 36A 55A 73A 109A 145A 181A 218A 291A 364A |
Penal display |
LCD | Chinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge current, accident display, warning |
Environment | |
Temperatyre | 0ºC-40 ºC |
Humidity | 0-95%(no condensing) |
Storage temperature | -25 ºC-55 ºC |
Altitude | <1500m |
Physical features |
Weight(KG) | Net | 230 258 350 400 480 580 650 900 950 |
Gross | 250 285 380 425 500 600 675 925 988 |
Domension(W×D×Hmm) | 800×600×2260 | 800×800×2260 | 800×1200×2260 |
Optional | RS485/SNMP/Harmonic compensation cabinet/Input and output isolation cabinet/Ligh protection device/Bypass stablelized cabinet/Customized appearannce and size |
Note:Product specifications are subject to change without further notice.
Address:
Building B6, Junfeng Industrial Park, Fuhai Sub-Distric, Bao′an District, Shenzhen City, Guangdong Province, 518103 P. R. China, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Security & Protection
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Shenzhen CONSNANT Technology Co., Ltd. (simple name: CONSNANT) is a professional manufacturer engaged in research, development and production of UPS (Uninterruptible Power Supply) including the Modular UPS, Outdoor & Indoor UPS, Industrial special UPS, Low Frequency & High Frequency Online UPS and Solar Power System both for home appliance and telecom equipments.
Our product has obtained the CE, ISO 9001, ISO 14001 and local Chinese TLC certificates. Having reached good sales results in China, we are now expanding our sales overseas.
We are proud of the fact that most of our company′s engineering staff is well-qualified and has gained experience in relevant fields more than 10 years. In order to protect your equipment from electrical supply network instability, we offer innovative solutions that obtain higher availability systems, improve efficiency and offer flexible solutions to meet specific needs and range of application. The UPS product is widely used in data and computing centers, finance institutions, banks, within industry and medical fields.
We welcome any kind of collaboration, will enjoy any opportunities of dealing with new costumers: From distributors to ultimate consumers, undertake both wholesale and retail orders, including the sale of finished goods or parts.
If you start work with us, you will not only get high-quality product at reasonable price, but also maintain the profitable conditions for further years.
We are located in the world-famous High-Tech center - Shenzhen city, China. Our factory is close to airport. If you are lucky to visit the city, you are kindly welcomed to visit our factory.